这个例子展示了如何从电阻式温度器件(RTD)获取温度数据并显示读数。该设备安装在PC机箱内,以监测内部温度变化。
要发现支持桥接传感器测量的设备,请访问返回的表中的设金宝app备daqlist
命令。这个例子使用了National Instruments®CompactDAQ Chassis NI cDAQ-9178中的NI 9219模块。这是一个24位通用模拟输入模块,是机箱中的模块7。
d = daqlist (“倪”)
d = 12×4表的DeviceID DeviceInfo描述模型 ___________ __________________________________ _____________ ____________________ " cDAQ1Mod1”“国家仪器NI 9205”“NI 9205”[1×1采集。DeviceInfo] "cDAQ1Mod2" "National Instruments NI 9263" "NI 9263" [1×1 daq。"cDAQ1Mod3" "National Instruments NI 9234" "NI 9234" [1×1 daq。DeviceInfo] "cDAQ1Mod4" "National Instruments NI 9201" "NI 9201" [1×1 daq。DeviceInfo] "cDAQ1Mod5" "National Instruments NI 9402" "NI 9402" [1×1 daq。DeviceInfo] "cDAQ1Mod6" "National Instruments NI 9213" "NI 9213" [1×1 daq。"cDAQ1Mod7" "National Instruments NI 9219" "NI 9219" [1×1 daq。"cDAQ1Mod8" "National Instruments NI 9265" "NI 9265" [1×1 daq。DeviceInfo] "Dev1" "National Instruments PCIe-6363" "PCIe-6363" [1×1 daq. exe] "Dev1"DeviceInfo]"Dev2" "National Instruments NI ELVIS II" "NI ELVIS II" [1×1 daq.DeviceInfo] "Dev3" "National Instruments PCIe-6363" "PCIe-6363" [1×1 daq.DeviceInfo] "Dev4" "National Instruments PCIe-6363" "PCIe-6363" [1×1 daq.DeviceInfo]
deviceInfo = d {7,“DeviceInfo”}
deviceInfo = ni: National Instruments ni 9219(设备ID: 'cDAQ1Mod7')模拟输入支持:9个范围支持0.1到100金宝app.0扫描/秒4通道('ai0','ai1','ai2','ai3')该模块位于名为“cDAQ1”的cDAQ-9178底盘的7号槽位。
创建一个数据采集,并添加一个模拟输入通道RTD
测量类型。
dq =采集(“倪”);dq。率= 30;ch = addinput (dq,“cDAQ1Mod7”,“ai3”,“RTD”);
参考传感器数据表,匹配相应的值。在本例中,使用了Omega®公司的SA1-RTD系列传感器。设置单位“华”
, RTD类型“Pt3851”
,将RTD电路配置为“FourWire”
,将电阻设置为100欧姆。
ch.Units =“华”;ch.RTDType =“Pt3851”;ch.RTDConfiguration =“FourWire”;ch.R0 = 100;
默认为ADC定时模式ADCTimingMode
通道的“HighResolution”
.设置ADCTimingMode
来“高速”
.
ch.ADCTimingMode =“高速”;
使用读
获取数据的命令。
数据= read(dq, seconds(1));(数据。时间,data.cDAQ1Mod7_ai3);degreeSign = 176;ylabel (sprintf (“温度(% cF)”degreeSign));