This example shows how to set fixed-point data types by instrumenting MATLAB® code for min/max logging and using the tools to propose data types.

The functions you will use are:

The Unit Under Test

The function that you convert to fixed-point in this example is a second-order direct-form 2 transposed filter. You can substitute your own function in place of this one to reproduce these steps in your own work.

function[y,z] = fi_2nd_order_df2t_filter(b,a,x,y,z)fori=1:length(x) y(i) = b(1)*x(i) + z(1); z(1) = b(2)*x(i) + z(2) - a(2) * y(i); z(2) = b(3)*x(i) - a(3) * y(i);endend

For a MATLAB® function to be instrumented, it must be suitable for code generation. For information on code generation, see the reference page forbuildInstrumentedMex. A MATLAB® Coder™ license is not required to usebuildInstrumentedMex.

In this function the variablesyandzare used as both inputs and outputs. This is an important pattern because:

  • You can set the data type ofyandzoutside the function, thus allowing you to re-use the function for both fixed-point and floating-point types.

  • The generated C code will createyandzas references in the function argument list. For more information about this pattern, see the documentation under Code Generation from MATLAB® > User's Guide > Generating Efficient and Reusable Code > Generating Efficient Code > Eliminating Redundant Copies of Function Inputs.

Run the following code to copy the test function into a temporary directory so this example doesn't interfere with your own work.

tempdirObj = fidemo.fiTempdir('fi_instrumentation_fixed_point_filter_demo');
copyfile(fullfile(matlabroot,'toolbox','fixedpoint','fidemos','+fidemo',...'fi_2nd_order_df2t_filter.m'),'.','f');

Run the following code to capture current states, and reset the global states.

FIPREF_STATE = get(fipref); reset(fipref)

Data Types Determined by the Requirements of the Design

In this example, the requirements of the design determine the data type of inputx. These requirements are signed, 16-bit, and fractional.

N = 256; x = fi(zeros(N,1),1,16,15);

The requirements of the design also determine the fixed-point math for a DSP target with a 40-bit accumulator. This example uses floor rounding and wrap overflow to produce efficient generated code.

F = fimath('RoundingMethod','Floor',...'OverflowAction','Wrap',...'ProductMode','KeepLSB',...'ProductWordLength',40,...'SumMode','KeepLSB',...'SumWordLength',40);

The following coefficients correspond to a second-order lowpass filter created by

[num,den] = butter(2,0.125)

The values of the coefficients influence the range of the values that will be assigned to the filter output and states.

num = [0.0299545822080925 0.0599091644161849 0.0299545822080925]; den = [1 -1.4542435862515900 0.5740619150839550];

The data type of the coefficients, determined by the requirements of the design, are specified as 16-bit word length and scaled to best-precision. A pattern for creatingfiobjects from constant coefficients is:

1. Cast the coefficients tofi对象使用默认round-to-nearest和坐urate overflow settings, which gives the coefficients better accuracy.

2. Attachfimathwith floor rounding and wrap overflow settings to control arithmetic, which leads to more efficient C code.

b = fi(num,1,16); b.fimath = F; a = fi(den,1,16); a.fimath = F;

Hard-code the filter coefficients into the implementation of this filter by passing them as constants to thebuildInstrumentedMexcommand.

B = coder.Constant(b); A = coder.Constant(a);

数据类型由Coeffic的值决定ients and Inputs

The values of the coefficients and values of the inputs determine the data types of outputyand state vectorz. Create them with a scaled double datatype so their values will attain full range and you can identify potential overflows and propose data types.

yisd = fi(zeros(N,1),1,16,15,'DataType','ScaledDouble','fimath',F); zisd = fi(zeros(2,1),1,16,15,'DataType','ScaledDouble','fimath',F);

Instrument the MATLAB® Function as a Scaled-Double MEX Function

To instrument the MATLAB® code, you create a MEX function from the MATLAB® function using thebuildInstrumentedMexcommand. The inputs tobuildInstrumentedMexare the same as the inputs tofiaccel, butbuildInstrumentedMexhas nofi-object restrictions. The output ofbuildInstrumentedMexis a MEX function with instrumentation inserted, so when the MEX function is run, the simulated minimum and maximum values are recorded for all named variables and intermediate values.

Use the'-o'option to name the MEX function that is generated. If you do not use the'-o'option, then the MEX function is the name of the MATLAB® function with'_mex'appended. You can also name the MEX function the same as the MATLAB® function, but you need to remember that MEX functions take precedence over MATLAB® functions and so changes to the MATLAB® function will not run until either the MEX function is re-generated, or the MEX function is deleted and cleared.

buildInstrumentedMexfi_2nd_order_df2t_filter...-ofilter_scaled_double...-args{B,A,x,yisd,zisd}

Test Bench with Chirp Input

The test bench for this system is set up to run chirp and step signals. In general, test benches for systems should cover a wide range of input signals.

The first test bench uses a chirp input. A chirp signal is a good representative input because it covers a wide range of frequencies.

t = linspace(0,1,N);% Time vector from 0 to 1 secondf1 = N/2;% Target frequency of chirp set to Nyquistxchirp = sin(pi*f1*t.^2);% Linear chirp from 0 to Fs/2 Hz in 1 secondx(:) = xchirp;% Cast the chirp to fixed-point

Run the Instrumented MEX Function to Record Min/Max Values

The instrumented MEX function must be run to record minimum and maximum values for that simulation run. Subsequent runs accumulate the instrumentation results until they are cleared withclearInstrumentationResults.

Note that the numerator and denominator coefficients were compiled as constants so they are not provided as input to the generated MEX function.

ychirp = filter_scaled_double(x,yisd,zisd);

The plot of the filtered chirp signal shows the lowpass behavior of the filter with these particular coefficients. Low frequencies are passed through and higher frequencies are attenuated.

clf plot(t,x,'c',t,ychirp,'bo-') title('Chirp') legend('Input','Scaled-double output') figure(gcf); drawnow;

Show Instrumentation Results with Proposed Fraction Lengths for Chirp

TheshowInstrumentationResultscommand displays the code generation report with instrumented values. The input toshowInstrumentationResultsis the name of the instrumented MEX function for which you wish to show results.

This is the list of options to theshowInstrumentationResultscommand:

  • -defaultDT TDefault data type to propose for doubles, whereTis anumerictypeobject, or one of the strings{remainFloat, double, single, int8, int16, int32, int64, uint8, uint16, uint32, uint64}. The default isremainFloat.

  • -nocodeDo not show MATLAB code in the printable report. Display only the logged variables tables. This option only has effect in combination with the -printable option.

  • -optimizeWholeNumbersOptimize the word length of variables whose simulation min/max logs indicate that they were always whole numbers.

  • -percentSafetyMargin NSafety margin for simulation min/max, whereNrepresents a percent value.

  • -printableCreate a printable report and open in the system browser.

  • -proposeFLPropose fraction lengths for specified word lengths.

  • -proposeWLPropose word lengths for specified fraction lengths.

Potential overflows are only displayed forfiobjects with Scaled Double data type.

This particular design is for a DSP, where the word lengths are fixed, so use theproposeFLflag to propose fraction lengths.

showInstrumentationResultsfilter_scaled_double-proposeFL

Hover over expressions or variables in the instrumented code generation report to see the simulation minimum and maximum values. In this design, the inputs fall between -1 and +1, and the values of all variables and intermediate results also fall between -1 and +1. This suggests that the data types can all be fractional (fraction length one bit less than the word length). However, this will not always be true for this function for other kinds of inputs and it is important to test many types of inputs before setting final fixed-point data types.

Test Bench with Step Input

The next test bench is run with a step input. A step input is a good representative input because it is often used to characterize the behavior of a system.

xstep = [ones(N/2,1);-ones(N/2,1)]; x(:) = xstep;

Run the Instrumented MEX Function with Step Input

The instrumentation results are accumulated until they are cleared withclearInstrumentationResults.

ystep = filter_scaled_double(x,yisd,zisd); clf plot(t,x,'c',t,ystep,'bo-') title('Step') legend('Input','Scaled-double output') figure(gcf); drawnow;

Show Accumulated Instrumentation Results

Even though the inputs for step and chirp inputs are both full range as indicated byxat 100 percent current range in the instrumented code generation report, the step input causes overflow while the chirp input did not. This is an illustration of the necessity to have many different inputs for your test bench. For the purposes of this example, only two inputs were used, but real test benches should be more thorough.

showInstrumentationResultsfilter_scaled_double-proposeFL

Apply Proposed Fixed-Point Properties

To prevent overflow, set proposed fixed-point properties based on the proposed fraction lengths of 14-bits foryandzfrom the instrumented code generation report.

At this point in the workflow, you use true fixed-point types (as opposed to the scaled double types that were used in the earlier step of determining data types).

yi = fi(zeros(N,1),1,16,14,'fimath',F); zi = fi(zeros(2,1),1,16,14,'fimath',F);

Instrument the MATLAB® Function as a Fixed-Point MEX Function

Create an instrumented fixed-point MEX function by using fixed-point inputs and thebuildInstrumentedMexcommand.

buildInstrumentedMexfi_2nd_order_df2t_filter...-ofilter_fixed_point...-args{B,A,x,yi,zi}

Validate the Fixed-Point Algorithm

After converting to fixed-point, run the test bench again with fixed-point inputs to validate the design.

Validate with Chirp Input

Run the fixed-point algorithm with a chirp input to validate the design.

x(:) = xchirp; [y,z] = filter_fixed_point(x,yi,zi); [ysd,zsd] = filter_scaled_double(x,yisd,zisd); err = double(y) - double(ysd);

Compare the fixed-point outputs to the scaled-double outputs to verify that they meet your design criteria.

clf subplot(211);plot(t,x,'c',t,ysd,'bo-',t,y,'mx') xlabel('Time (s)'); ylabel('Amplitude') legend('Input','Scaled-double output','Fixed-point output'); title('Fixed-Point Chirp') subplot(212);plot(t,err,'r');title('Error');xlabel('t'); ylabel('err'); figure(gcf); drawnow;

Inspect the variables and intermediate results to ensure that the min/max values are within range.

showInstrumentationResultsfilter_fixed_point

Validate with Step Inputs

Run the fixed-point algorithm with a step input to validate the design.

Run the following code to clear the previous instrumentation results to see only the effects of running the step input.

clearInstrumentationResultsfilter_fixed_point

Run the step input through the fixed-point filter and compare with the output of the scaled double filter.

x(:) = xstep; [y,z] = filter_fixed_point(x,yi,zi); [ysd,zsd] = filter_scaled_double(x,yisd,zisd); err = double(y) - double(ysd);

Plot the fixed-point outputs against the scaled-double outputs to verify that they meet your design criteria.

clf subplot(211);plot(t,x,'c',t,ysd,'bo-',t,y,'mx') title('Fixed-Point Step'); legend('Input','Scaled-double output','Fixed-point output') subplot(212);plot(t,err,'r');title('Error');xlabel('t'); ylabel('err'); figure(gcf); drawnow;

Inspect the variables and intermediate results to ensure that the min/max values are within range.

showInstrumentationResultsfilter_fixed_point

Run the following code to restore the global states.

fipref(FIPREF_STATE); clearInstrumentationResultsfilter_fixed_pointclearInstrumentationResultsfilter_scaled_doubleclearfi_2nd_order_df2t_filter_fixed_instrumentedclearfi_2nd_order_df2t_filter_float_instrumented

Run the following code to delete the temporary directory.

tempdirObj.cleanUp;%#ok<*ASGLU>