Fault-Tolerant Control of a Passenger Jet
This example shows how to tune a fixed-structure controller for multiple operating modes of the plant.
Background
This example deals with fault-tolerant flight control of passenger jet undergoing outages in the elevator and aileron actuators. The flight control system must maintain stability and meet performance and comfort requirements in both nominal operation and degraded conditions where some actuators are no longer effective due to control surface impairment. Wind gusts must be alleviated in all conditions. This application is sometimes calledreliable controlas aircraft safety must be maintained in extreme flight conditions.
Aircraft Model
The control system is modeled in Simulink.
addpath(fullfile(matlabroot,'examples','control','main'))% add example dataopen_system('faultTolerantAircraft')
The aircraft is modeled as a rigid 6th-order state-space system with the following state variables (units are mph for velocities and deg/s for angular rates):
u: x-body axis velocity
w: z-body axis velocity
q: pitch rate
v: y-body axis velocity
p: roll rate
r: yaw rate
The state vector is available for control as well as the flight-path bank angle rate mu (deg/s), the angle of attack alpha (deg), and the sideslip angle beta (deg). The control inputs are the deflections of the right elevator, left elevator, right aileron, left aileron, and rudder. All deflections are in degrees. Elevators are grouped symmetrically to generate the angle of attack. Ailerons are grouped anti-symmetrically to generate roll motion. This leads to 3 control actions as shown in the Simulink model.
The controller consists of state-feedback control in the inner loop and MIMO integral action in the outer loop. The gain matricesKi
andKx
are 3-by-3 and 3-by-6, respectively, so the controller has 27 tunable parameters.
Actuator Failures
We use a 9x5 matrix to encode the nominal mode and various actuator failure modes. Each row corresponds to one flight condition, a zero indicating outage of the corresponding deflection surface.
OutageCases = [...1 1 1 1 1;...% nominal operational mode0 1 1 1 1;...% right elevator outage1 0 1 1 1;...% left elevator outage1 1 0 1 1;...% right aileron outage1 1 1 0 1;...% left aileron outage1 0 0 1 1;...% left elevator and right aileron outage0 1 0 1 1;...% right elevator and right aileron outage0 1 1 0 1;...% right elevator and left aileron outage1 0 1 0 1;...% left elevator and left aileron outage];
Design Requirements
The controller should:
Provide good tracking performance in mu, alpha, and beta in nominal operating mode with adequate decoupling of the three axes
Maintain performance in the presence of wind gust of 10 mph
Limit stability and performance degradation in the face of actuator outage.
To express the first requirement, you can use an LQG-like cost function that penalizes the integrated tracking errore
and the control effortu
:
The diagonal weightsandare the main tuning knobs for trading responsiveness and control effort and emphasizing some channels over others. Use theWeightedVariance
requirement to express this cost function, and relax the performance weightby a factor 2 for the outage scenarios.
We = diag([10 20 15]); Wu = eye(3);% Nominal tracking requirementSoftNom = TuningGoal.WeightedVariance('setpoint',{'e','u'}, blkdiag(We,Wu), []); SoftNom.Models = 1;% nominal model% Tracking requirement for outage conditionsSoftOut = TuningGoal.WeightedVariance('setpoint',{'e','u'}, blkdiag(We/2,Wu), []); SoftOut.Models = 2:9;% outage scenarios
For wind gust alleviation, limit the variance of the error signale
due to the white noisewg
driving the wind gust model. Again use a less stringent requirement for the outage scenarios.
% Nominal gust alleviation requirementHardNom = TuningGoal.Variance('wg','e',0.02); HardNom.Models = 1;% Gust alleviation requirement for outage conditionsHardOut = TuningGoal.Variance('wg','e',0.1); HardOut.Models = 2:9;
Controller Tuning for Nominal Flight
Set the wind gust speed to 10 mph and initialize the tunable state-feedback and integrators gains of the controller.
GustSpeed = 10; Ki = eye(3); Kx = zeros(3,6);
Use theslTuner
interface to set up the tuning task. List the blocks to be tuned and specify the nine flight conditions by varying theoutage
variable in the Simulink model. Because you can only vary scalar parameters inslTuner
, independently specify the values taken by each entry of theoutage
vector.
OutageData = struct(...'Name',{'outage(1)','outage(2)','outage(3)','outage(4)','outage(5)'},...'Value',mat2cell(OutageCases,9,[1 1 1 1 1])); ST0 = slTuner('faultTolerantAircraft',{'Ki','Kx'},OutageData);
Usesystune
调整控制器收益第二名字l requirements. Treat the wind gust alleviation as a hard constraint.
[ST,fSoft,gHard] = systune(ST0,SoftNom,HardNom);
Final: Soft = 22.6, Hard = 0.99972, Iterations = 300
Retrieve the gain values and simulate the responses to step commands inmu, alpha, beta
for the nominal and degraded flight conditions. All simulations include wind gust effects, and the red curve is the nominal response.
Ki = getBlockValue(ST,'Ki'); Ki = Ki.d; Kx = getBlockValue(ST,'Kx'); Kx = Kx.d;% Bank-angle setpoint simulationplotResponses(OutageCases,1,0,0);
% Angle-of-attack setpoint simulationplotResponses(OutageCases,0,1,0);
% Sideslip-angle setpoint simulationplotResponses(OutageCases,0,0,1);
The nominal responses are good but the deterioration in performance is unacceptable when faced with actuator outage.
Controller Tuning for Impaired Flight
To improve reliability, retune the controller gains to meet the nominal requirement for the nominal plant as well as the relaxed requirements for all eight outage scenarios.
[ST,fSoft,gHard] = systune(ST0,[SoftNom;SoftOut],[HardNom;HardOut]);
Final: Soft = 25.7, Hard = 0.99643, Iterations = 511
The optimal performance (square root of LQG cost) is only slightly worse than for the nominal tuning (26 vs. 23). Retrieve the gain values and rerun the simulations (red curve is the nominal response).
Ki = getBlockValue(ST,'Ki'); Ki = Ki.d; Kx = getBlockValue(ST,'Kx'); Kx = Kx.d;% Bank-angle setpoint simulationplotResponses(OutageCases,1,0,0);
% Angle-of-attack setpoint simulationplotResponses(OutageCases,0,1,0);
% Sideslip-angle setpoint simulationplotResponses(OutageCases,0,0,1);
The controller now provides acceptable performance for all outage scenarios considered in this example. The design could be further refined by adding specifications such as minimum stability margins and gain limits to avoid actuator rate saturation.
rmpath(fullfile(matlabroot,'examples','control','main'))% remove example data